Technical specifications

Technical Specifications

The metallic tiles by AURUM keep the technical characteristics of origin (glazed stoneware and faience…). AURUM's tiles treated with the patented process offer a much higher mechanical and chemical resistance than those gilded by traditional methods applying precious metals.

Aurum Design

Faience product · Wall use · NF EN 176

AURUM's metallic tiles' technical characteristics for wall use according to NF EN 176.

Type of test Required value by EN 176 AURUM's result Type of process NF EN 176
1. Size's allowance Max. ±0.75 OK NF EN 98
ISO 10545-2
2. Scratch resistance Min. 3 Mohs OK NF EN 101
3. Linear dilatation between 20 and 100°C in 1°C Max. 9×10⁻⁶ OK NF EN 103
ISO 10545-8
4. Resistance to temperature variation Required OK NF EN 104
5. Colours stability and stability to light (UV resistance) Required OK
6.1. Glaze's resistance — Resistance to stanning Required OK NF EN 122
ISO 10545-14
6.2. Resistance to chemical products Required OK NF EN 106
ISO 10545-13
6.3. Resistance to alkalin products Only required if specially demanded OK NF EN 122

Note: the required technical characteristics are regularly checked by AURUM's laboratory.

Aurum Ceralux

Stoneware product · Interior & exterior · NF EN 176

Technical characteristics of AURUM Ceralux metallic tiles (glazed stoneware) for interior and exterior use according to NF EN 176. Depending on the intrinsic qualities of the tiles, exterior use is possible.

Type of test Required value by EN 176 AURUM's result Type of process NF EN 176
1. Size's allowance Max. ±0.75 OK NF EN 98
ISO 10545-2
2. Water absorption < 3% OK NF EN 99
ISO 10545-3
3. Flexion resistance Min. 20 N/mm² OK NF EN 100
ISO 10545-4
4. Glaze hardness Min. 5 Mohs OK NF EN 101
5. Linear dilatation between 20 and 100°C in 1°C Max. 9×10⁻⁶ OK NF EN 103
ISO 10545-8
6. Resistance to temperature variation Required OK NF EN 104
7. Frost resistance Required OK NF EN 202
ISO 10545-12
8. Colours stability and stability to light (UV resistance) Required OK
9. Resistance to chemical and alkalin products Required OK NF EN 106
ISO 10545-13
10. Abrasion resistance Class 1 OK NF EN 154
ISO 10545-7

Note: the required technical characteristics are regularly checked by AURUM's laboratory.

A technical question?

Our team is available to answer any questions about the technical characteristics of our products.

Contact us